M&H 6090 Stage V Emissions Hazardous Area Engine

(205 kW (275 HP) @ 2200 RPM – 317 kW (425 HP) @ 2000 - 2200 RPM)

Emissions reductions from Stage 1 to M&H Stage V

Based on 130 to 560 kW NRMM engine power output range

Reduction in CO 99.78%
Reduction in NOX 99.79%
Reduction in PM 99.81%

Specifications

Hazardous Stage V 6090
Hazardous Stage V 6090

I-6, 4-Stroke-Cycle-Diesel

Emissions – Stage V / IMO lll / BSO / CH VASm

Weight, Net Dry (approx) – 1,097 kg (2,418 lb)

Oil Change Interval – 500 hr

Rotation (from flywheel end) – Counterclockwise

Flywheel and flywheel housing – SAE options available

Max. Exhaust Backpressure – 27.0 kPa (109 in. water)

Fuel Consumption – 214 g/kWh (0.352 lb/hp-hr)

Rated Power – 317 kW - 425 hp

Rated Speed – 2200 rpm

Peak Torque Speed – 1600 rpm

Rated Torque – 1,376 N·m - 1018 lb-ft

BMEP Rated – 1,925 kPa - 279 psi

Noise @ 1 m dB(A) – 98

Performance Data 317 kW (425 HP) @ 2200 RPM

Hazardous Stage V 6090 Data Table
Air Inlet System Corrosion resistant aftercooler core, light - duty air cleaner
Cooling System Gear-driven jacket water pump
Inlet Air System Inlet shut down valve and flame trap to comply with hazardous standards
Gas Detector Inlet air system fitted with gas detector
Exhaust System Fully thermal protected exhaust manifold, turbocharger and after treatment system
Exhaust Gas Cooler Fully protected exhaust gas cooler to meet T3 surface and exhaust gas temperatures
Spark Arrestor Spark arrestor to meet hazardous area standards
Protection System Complete exhaust system, turbochargers and after treatment system fully protected to meet T3 surface temperature requirements
Aftertreatment DOC / DPF / SCR
Fuel System Fuel priming pump, fuel transfer pump, fuel filter — RH or LH service, flexible fuel lines
Lube System Crankcase breather, engine oil cooler, oil filter — RH or LH service, oil dipstick — RH or LH option, oil filler, deep sump oil pan, gear-driven oil pump
Instrumentation 12V / 24V instrument panel.
Protection System 12 or 24V electronic shutdown
Control System Fully integrated control system for engine and hazardous area shut down requirements. This can also be fully configured to provide complete package control and remote monitoring if required.

Stage V Engine Physical Data 6090

Hazardous Stage V 4045
Hazardous Stage V 4045
Engine Model (Stage V) Aftertreatment Location Total Weight Kgs (lbs) Length (A) mm (ins) Width (B) mm (ins) Height (C) mm (ins)
6068 Rear 1395 (3076) 2600 (103) 960 (38) 1466 (58)

Note: All dimensions and weights given in the above table and in the engine data sheets are indicative only. Definitive dimensions and weights will be confirmed at order placement.

Stage V Complete System Physical Data 6090

Stage V 4045 Complete System
Stage V 4045 Complete System
Engine Model (Stage V) Exhaust Gas Cooler Location Total Weight Kgs (lbs) Length (A) mm (ins) Width (B) mm (ins) Height (C) mm (ins)
4045 Side 1725 (3802) 2600 (103) 1440 (56) 1466 (58)

Note: All dimensions and weights given in the above table and in the engine data sheets are indicative only. Definitive dimensions and weights will be confirmed at order placement.

M&H Stage V Hazardous Area Engines Features and Benefits

Complete System

The engine will be supplied as a packaged system with the relevant additional parts including exhaust gas cooler, inlet shut down valve, inlet flame trap, etc.

The complete system has been designed and developed with our partners, who are specialists in hazardous protection systems, which ensures a fully integrated and optimized system.

As we are supplying a complete system, it provides the customer with a complete solution for them to finish package.

Accreditation

The complete system will have a declaration of conformity to the various hazardous area standards for Zone 2 and Class 1 / Div 2, for gases that will be provided by a third party notified body.

Warranty

M&H Stage V engines come with a three-year warranty as standard. Warranty conditions are – one-year unlimited hours, three years total 5,000 hours maximum. Extended warranty is available at an extra cost for an additional two years.

Service and support

Service and support contracts are available for the warranty period and beyond. Service and support from our expanded service dealer team ensures prime operation of your engine and a long service life.

Oil change

500 hours standard oil change intervals. Additional high specification filtration systems can be fitted to extend oil change intervals to up to 1,000 hours.

Either-side Service

Oil fill and dipstick combinations, remote oil filter and fuel water separator can be configured for easier packaging, service access, application and service flexibility to provide installation convenience plus fast and easy maintenance

Engine Jacket Water Circuit cooling

Suitable for radiator cooling. Combined engine jacket water circuit and exhaust gas cooler water circuit pump.

Exhaust after treatment for Stage V units.

M&H Engineering engines use EGR, DPF, DOC and SCR exhaust systems to meet the Stage V emission legislation requirements.

Protection

All systems are protected both mechanically and electrically in accordance with the relevant hazardous area standards requirements.

Regeneration Mode

The Stage V engine is fully capable of taking full load during the exhaust after treatment regeneration cycle – no increase or reduction of engine rpm is required during cycle.
Class leading exhaust temperature management system which maintains after treatment temperatures at optimum temperatures regardless of loading.
Fully automatic regeneration system.